• Hpht Filter Press Model Hfp-71, Single Capped Cell for Filter Paper
  • Hpht Filter Press Model Hfp-71, Single Capped Cell for Filter Paper
  • Hpht Filter Press Model Hfp-71, Single Capped Cell for Filter Paper
  • Hpht Filter Press Model Hfp-71, Single Capped Cell for Filter Paper
  • Hpht Filter Press Model Hfp-71, Single Capped Cell for Filter Paper
  • Hpht Filter Press Model Hfp-71, Single Capped Cell for Filter Paper

Hpht Filter Press Model Hfp-71, Single Capped Cell for Filter Paper

After-sales Service: 1 Year
Warranty: 1 Year
Certification: ISO 9001:2000
Power Source: Electric
Operation Pressure: Atmospheric Pressure
Applicable Medium: Crude Oil
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
HPHT Filter Press Model HFP-71,
Structure
Vertical
Transport Package
Export Packaging
Trademark
DEENPU
Origin
China
HS Code
84314310
Production Capacity
1000

Product Description

HPHT Filter Press Model HFP-71,Single Capped Cell for Filter Paper
 
Hpht Filter Press Model Hfp-71, Single Capped Cell for Filter Paper

The HTHP (High Temperature, High Pressure) Filter Press is designed for testing drilling fluids under elevated temperatures and pressures. The unit simulates various downhole conditions and provides a reliable method for determining the effectiveness of the material being tested.

 

The High Pressure-High Temperature (HPHT) Filter Presses are an efficient means of evaluating the filtration properties of drilling muds at high temperatures and pressures. The cells have a filtering area of 3.5 in2 and can be operated at pressures up to 900 psi with the compact, easily attached CO2 pressuring unit provided.

 

The Model HFP-42 Series HTHP Filter Press is equipped with a 175 mL sample cell and the working temperatures above 350°F (177°C), making it ideal for laboratory use. Also included is a regulator manifold system for connecting to bottled nitrogen for higher pressures up to1, 800 PSI (12,400 kPa

 

The Model HFP-71 Series HTHP Filter Press is equipped with a 500 mL sample cell and the working temperatures above 500°F (260°C), making it ideal for laboratory use. Also included is a regulator manifold system for connecting to bottled nitrogen for higher pressures up to1, 800 PSI (12,400 kPa)

 
Filter Press HTHP Specification

 

Part No.

Model  

Specification

170-02

HFP-42

Single Capped   Cell for Filter Paper

 

The   digital system is accurate and controllable.

Maximum   Temperature : 350ºF (177ºC)

Maximum   Pressure Cell: 1800 psig (12.4 MPa)

Maximum   Backpressure: 750 psig (5.17 MPa)

Sample   Cell Volume: 175 ml

Receiver   Volume: 15 ml

Filtering   Area: 3.5 in2 (22.58 cm2)

Pressure   Connection: Nitrogen or Carbon Dioxide

Heating   Capacity :400 Watts

Power   Requirement: 115/230 VAC, Frequency 50/60 Hz

Size:   320×320×650 mm

Weight:36kg

170-02D

HFP-42D

Double Capped Cell for Ceramic Disks.

 

The   digital system is accurate and controllable.

Maximum   Temperature : 350ºF (177ºC)

Maximum   Pressure Cell: 1800 psig (12.4 MPa)

Maximum   Backpressure: 750 psig (5.17 MPa)

Sample   Cell Volume: 175 ml

Receiver   Volume: 15 ml

Filtering   Area: 3.5 in2 (22.58 cm2)

Pressure   Connection: Nitrogen or Carbon Dioxide

Heating   Capacity :400 Watts

Power   Requirement: 115/230 VAC, Frequency 50/60 Hz

Size:   320×320×650 mm

Weight:36kg

171-02

HFP-71

Single Capped   Cell for Filter Paper

 

The   digital system is accurate and controllable.

Maximum   Temperature : 500ºF   (260ºC)

Maximum   Pressure Cell: 1800 psig (12.4 MPa)

Maximum   Backpressure: 750 psig (5.17 MPa)

Sample   Cell Volume: 500 ml

Receiver   Volume: 100 ml

Filtering   Area: 3.5 in2 (22.58 cm2)

Pressure   Connection: Nitrogen or Carbon Dioxide

Heating   Capacity :800 Watts

Power   Requirement: 115/230 VAC, Frequency 50/60 Hz

Size:   720×440×340 mm
 Weight:45kg

171-02C

HFP-71C

Double Capped Cell for Cement Screens

 

The   digital system is accurate and controllable.

Maximum   Temperature : 500ºF   (260ºC)

Maximum   Pressure Cell: 1800 psig (12.4 MPa)

Maximum   Backpressure: 750 psig (5.17 MPa)

Sample   Cell Volume: 500 ml

Receiver   Volume: 100 ml

Filtering   Area: 3.5 in2 (22.58 cm2)

Pressure   Connection: Nitrogen or Carbon Dioxide

Heating   Capacity :800 Watts

Power   Requirement: 115/230 VAC, Frequency 50/60 Hz

Size:   720×440×340 mm
 Weight:45kg

171-02D

HFP-71D

Double Capped Cell for Ceramic Disks.

 

The   digital system is accurate and controllable.

Maximum   Temperature : 500ºF   (260ºC)

Maximum   Pressure Cell: 1800 psig (12.4 MPa)

Maximum   Backpressure: 750 psig (5.17 MPa)

Sample   Cell Volume: 500 ml

Receiver   Volume: 100 ml

Filtering   Area: 3.5 in2 (22.58 cm2)

Pressure   Connection: Nitrogen or Carbon Dioxide

Heating   Capacity :800 Watts

Power   Requirement: 115/230 VAC, Frequency 50/60 Hz

Size:   720×440×340 mm
Weight:45kg

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now